Skip to content
Energy and Sustainability

Compressed Air Leak Rate

The share of compressed air production lost through leaks.

Formula

Leak rate = Air delivered with no consumers running / Air delivered in production

or measured with a leak-down test

Worked examples

  1. 01Sunday test, all consumers off: compressors deliver 6.4 cubic meters per minute; production average 20 cubic meters per minute. Leak rate = 32.0%.
  2. 02Energy: 6.4 cubic meters per minute at about 0.11 kWh per cubic meter = 42.2 kWh per hour, over 6,000 hours = 253,440 kWh.
  3. 03After repairing 46 tagged leaks: leak flow 3.1 cubic meters per minute, rate 15.5%, saving 130,680 kWh per year.

Pitfalls

  • Testing at a lower pressure than in production underestimates the leaks.
  • Tagging leaks without a repair process does not save energy.

Related KPIs

Newsletter

One Lean idea.
Every two weeks.