Skip to content
Energy and Sustainability

Energy Intensity

Energy used per good unit, per metric ton or per production hour.

Formula

Energy intensity = Energy consumption / Good units produced

Worked examples

  1. 01Plant year: 4,200 MWh electricity + 1,800 MWh gas = 6,000 MWh for 600,000 good parts. Intensity = 6,000,000 / 600,000 = 10.0 kWh per part.
  2. 02Machining area: 186,000 kWh in a month for 38,500 parts = 4.83 kWh per part.
  3. 03Foundry: 2,900 MWh for 4,100 metric tons of castings = 707 kWh per metric ton.

Pitfalls

  • Base load spread over fewer units raises intensity in low-volume months.
  • Mixing electricity and gas in kWh is fine; mixing kWh and cost is not.

Related KPIs

Newsletter

One Lean idea.
Every two weeks.