Calibration answers one question: does this gauge still read right? The interval decides how long a wrong answer can stay unnoticed.
Four terms
- Calibration compares the gauge with a reference of known value and records the deviation. It changes nothing on the gauge.
- Adjustment corrects the gauge so that it reads right again.
- Traceability is an unbroken chain of comparisons from your gauge to a national standard, each with a record.
- Interim check is a short check at the workstation between calibrations, with a setting master or a reference part.
ISO 9001 asks for measuring equipment that is calibrated or verified against traceable standards at specified intervals. It does not say how many months. That decision is yours, and it needs a reason.
What a record must show
A result that says “passed” hides the most useful information. A calibration record should show the test points across the range, the values found, the reference used and the permissible error. If the gauge was adjusted, the values before the adjustment matter most, because they decide whether parts measured earlier are in doubt.
Internal or external
Calibrate internally what you have in numbers and can check with a few references: calipers, micrometers, indicators, plug gauges. Send the references themselves, measuring machines and rare gauges to a laboratory that is accredited for the quantity and range, for example under ISO/IEC 17025. In the example plant, 350 of 420 gauges are calibrated internally.
Starting intervals
The shaft line started with three values: 12 months for calipers, indicators, bore gauges and most micrometers, 6 months for micrometers at the grinding cell where tolerances are below 0.03 mm, and 24 months for plug gauges, thread gauges and setting masters. These are starting values of one plant. Use, wear and the risk of the characteristic decide.
Adjust by history
An interval should react to what calibration finds. A simple rule is enough:
| Last calibrations | New interval |
|---|---|
| Latest result out of tolerance | Half, at least 1 month |
| Last three results in tolerance without adjustment | One and a half times, at most 24 months |
| Anything else | Unchanged |
Applied to twelve gauges of the shaft line, the rule extended five intervals from 12 to 18 months, shortened one micrometer from 6 to 3 months and left six unchanged. The number of calibrations per year for these gauges moved from 15.0 to 15.3. The rule did not save work. It moved the work to the gauge that needed it.
The status date
On 23 November 2026, the list of the shaft line showed 36 gauges in use. Five of them were overdue, the oldest by 56 days, and four more were due within 30 days. Calibration on time was 31 of 36, or 86 percent. The target is 100 percent, every day. An overdue gauge is blocked. An extension by signature is not a calibration.
The plan
Count the due dates per month for the next twelve months. In the shaft line, 21 calibrations fall into that period, between one and three per month.
Three habits make it work. Gauges are called in one week before the due date and replaced from the cabinet. When all micrometers of one cell fall due together, half of them are moved forward by a month. And the supervisor gets the list of gauges due within 30 days every Monday.
The gap between calibrations
Six months between calibrations are six months in which a dropped gauge can stay unnoticed. A setting master at the workstation closes the gap: one reading per shift or week, written down, with a limit for blocking the gauge. It takes two minutes. Part 6 of this series shows what the missing two minutes cost the plant.
A calibrated gauge reads right. Whether it is the right gauge for the tolerance is a different question, and the subject of the next part.